THERMAL COMFORT
Some Like It Hot
by Alan Meier
Alan Meier is executive editor of Home Energy
This article, the second in Home Energy's tenth-anniversary series, originally appeared in 1986. It offers tips on how to keep warm in the winter while still conserving energy.
Almost everybody knows when they are cold, but it is difficult to
predict an individual's thermal comfort for a particular set of conditions. For
example, would somebody be comfortable wearing cotton pajamas in a 64deg.F room
while assembling an intricate jigsaw puzzle? Such questions may seem trivial
for everyday activities, where adjusting the thermostat or putting on a sweater
are simple alternatives, but predicting thermal comfort is critical for
astronauts, arctic oil drillers, and a scuba divers. In less esoteric
situations, such as indoor swimming pools, gymnasiums, auditoriums, and
environmentally controlled "clean rooms," thermal comfort is an important
design consideration.
A science based on quantifiable environmental parameters has evolved to predict
thermal comfort. Thermal comfort science permits auditors and retrofitters to
recognize comfort problems and propose more creative solutions.
What is Thermal Comfort?
The human body burns food and produces a significant amount of heat. A
sleeping adult generates about the same amount of heat as a 100 W light bulb.
An athlete at peak exertion generates over 1,000 W--about the output of a
portable space heater or hair dryer. If the body cannot easily rid itself of
the heat--be it 100 or 1,000 W--the physiological message sent to the brain is,
"I'm hot!" Overheating occurs because the body is unable to dispose of heat as
fast as it is produced. In cool situations, the rate of heat loss to the
environment exceeds the body's heat production ("I'm cold!").
While some heat is removed through breathing, heat loss through the skin is by
far the major path. Cold receptors in the skin signal the brain if the
temperature on the skin (or a limited area on the skin) drops at a rate faster
than 0.5deg.F per minute. The appearance of a cool draft, which can change
local air temperatures by 2deg.F in a matter of seconds, easily exceeds this
threshold.
The human body has evolved a remarkable thermoregulatory system. One response
is to increase thermal output to match the loss. The muscle tensions that cause
shivering, for example, can cause a three-fold increase in heat production. At
the same time, the body tries to cut heat loss by limiting blood flow to the
skin and extremities. A colder skin reduces heat loss. Skin temperatures are
generally well below 98deg.F at room temperature. The mean skin temperature of
a nude person at room temperature is only about 90deg.F. Feet temperatures drop
to less than 80deg. F!
In cold situations, the blood vessels near the surface constrict.
Vasoconstriction generally occurs in the extremities first, that is, the
fingers, hands, feet, nose, and so on. Once the blood vessels are fully
constricted, the skin acts similarly to clothing, and provides useful
insulation. Heat is also conducted from the warmer core to the surface through
the skin. Its insulation value depends on the thickness of the fat layer.
The Fundamental Trade-off
The familiar heat loss equation, Q = UA(Tin-Tout), governs the major
heat loss paths in a house. Most conservation measures try to reduce the rate
of heat loss, Q, by lowering the U-value, that is, increasing the thermal
resistance of the walls, ceiling, and windows. A few conservation strategies
try to reduce the surface area, A.
Another method of reducing heat loss is to reduce the temperature difference.
We can only affect the temperature inside the house, since the outside
temperature stubbornly refuses to bend to our will. A setback thermostat saves
energy but results in a colder, less comfortable home. But the intelligent
application of thermal comfort research permits occupant comfort at a lower air
temperature by improving other environmental parameters. (See Figure 1) These
measures rarely permit more than an 8deg.F offset, but even a 5deg.F drop in
thermostat setting over the whole winter can significantly lower the heating
bill--often by as much as 15%. In other cases, thermal comfort measures might
be used to make a home more comfortable without turning up the thermostat. Such
measures correspond to shifting to a higher line of thermal comfort in Figure 1.
Elements of Thermal Comfort
Most people wrongly equate thermal comfort with the temperature. In
fact, air temperature is only one of many factors affecting comfort. The major
factors can be viewed as personal (the insulation value of clothing, activity
level) and environmental (air temperature, mean radiant temperature of
surrounding surfaces, air speed, humidity).
Clothes Make the Man (Warm)
The "clo-value" of clothing closely corresponds to the R-value of
fiberglass and other building materials. Researchers in Denmark and the United
States have measured the clo-values of different clothing ensembles. By
definition, a nude person has a clo-value of 0.0, while a typical business suit
has a clo-value of 1.0. An Eskimo's cold-weather parka has a clo-value of about
4.0. Table 1 shows the clo-values for different items of clothing and
ensembles. There are also estimates of clo-values of animals' skins. The tiny
shrew's fur coat provides only a clo-0.3 whereas the polar bear's coat is about
clo-5. The relationship between clo-value and thermal comfort (for humans) is
shown in Figure 2.
Recommending that occupants wear more clothes is not always a good idea,
because people may see wearing warmer clothing as an unacceptable sacrifice.
But specific items of clothing, such as socks or a cap, may be accepted. Even
small increases in the occupants' clo-values can permit significant reductions
in the thermostat setting-as much as a few degrees--especially if the
thermostat-setter (or chief complainer) is a little warmer.
Keep Active!
One way to warm up is to increase heat output or, simply, to keep
active! The level of activity is measured in units of "mets" (short for
"metabolic units"). One met is defined as the rate of heat produced when a
person is quietly seated, and it corresponds to about 58 W per square meter of
body surface area. Since adults range in surface area from 1.5 to 2.0 square
meters, the heat produced by a sedentary adult is 90-115 Watts. Heavy work
corresponds to about 3 mets, but an athlete can achieve (briefly) 9 mets. Table 2 lists the met-values for several activities.
Even a little activity can improve thermal comfort. Table 2 shows that
switching from quietly sitting to standing can increase heat output 20%, which
is often sufficient to re-establish thermal comfort. Strenuous exercise
provides so much more heat that one can overheat even in cold conditions. (This
explains why careful consideration of thermal comfort is needed in gymnasiums
and swimming pools.)
Differing activity levels often explain different thermostat preferences. For
example, it is commonly believed that older people need higher temperatures to
keep comfortable. Research has shown that age does not significantly affect
thermal comfort preferences. However, older people are generally less active,
and the lower activity level requires a higher temperature to maintain
comfort.
When evaluating the feasibility of a thermostat setback, it is essential to
consider the activity levels of the occupants, especially if there are elderly
persons in the house. Recommending periodic calisthenics may improve their
health but you may also get you laughed out of the house. Still, people
sometimes forget that even a little activity can vastly increase their comfort.
The next group of thermal comfort factors are externally, rather than
personally, generated. These factors--air movement, mean radiant temperature,
and humi- dity--offer many retrofit opportunities. Again, the primary goal is
to reduce the air temperature (lower thermostat) while maintaining the level of
thermal comfort by increasing other thermal comfort factors. In other cases,
the goal is to increase thermal comfort without raising the thermostat
setting.
Avoiding the Draft
Air moving over the skin (or clothes) robs the body of heat. The source
of air movement may be natural convection, a fan or draft (forced convection),
or body movement caused by walking or running. In these situations, higher air
temperatures are necessary to maintain the same thermal comfort level (See
Figure 3). People are very sensitive to changes in air speed, and as Figure 3
shows, air movement can change the comfort temperature as much as 5deg.F under
typical domestic conditions. The peculiar elbows in the comfort curves in
Figure 3 reflect the destruction of the body's surface air film. As air speeds
increase above 0.4 feet per second, the surface air film collapses and ceases
to provide insulation. Heat loss increases markedly, which is reflected in the
rapid increase in the comfort temperature. Accurately measuring low air speeds
is expensive, but rough measures are possible. A "draft" exceeds 0.5 feet per
second. A hand-operated fan, held a few feet away, can create local air speeds
exceeding 1.2 feet per second.
House-tightening measures can significantly reduce air movement in a house. The
blower door is an effective tool in identifying leaks. Note that
house-tightening (that is, weatherstripping, leak-plugging, and other
infiltration reducing measures) saves energy two ways. Since it reduces air
infiltration, less air needs to be heated. Of secondary importance, the slower
air movement permits a lower thermostat setting. (Unfortunately, it is
impossible to translate reduced infiltration into lower air movement rates
because infiltration is so uneven.) Upon completion of a major
house-tightening, the retrofitter should recommend a 1-3deg.F thermostat
setback if the occupant wants to achieve maximum savings. On the other hand, if
occupants want a combination of savings and increased comfort, the thermostat
can stay at the original temperature.
Sometimes drafts are inevitable. For example, houses without vestibules suffer
from a blast of cold air (over 6 feet per second) each time an outside door is
opened. Even warm air moving at a high speed feels uncomfortable. Heat pumps
need high air flow through the ducts, and this often causes drafts near their
registers. In these situations, repositioning furniture, or possibly relocating
the most frequent activities, can lead to greater comfort. Deflectors on
heating registers are simple and effective. Sites of sedentary activities, such
as television-watching or card-playing, should be carefully assessed. Keep the
favorite television chair away from drafts!
Radiant Temperature
All objects lose heat through radiation. The sun's radiation is the most
familiar example. A person immediately senses the radiation when walking out of
the cool shade and into the sunlight. Many new bathrooms are equipped with
infrared lights to provide quick radiative heating. Radiant temperatures in a
building are an important, but subtle, factor in determining thermal comfort.
Radiative heat loss is totally unlike the familiar conductive heat loss. The
rate of radiative heat loss depends on the object's temperature. At the same
time, all the surfaces around an object are radiating heat towards the object.
The object's net radiative loss is therefore the difference between the heat it
loses (a function of the object's temperature) and the heat it gains (a
function of the surrounding surfaces' temperatures). Radiation is subtle
because radiative heat loss is essentially independent of the air temperature
around the object. People radiate heat, too, although the rate is much less
intense than the sun (because a human's temperature is only about 100deg.F).
The mean radiant temperature (MRT)--the area-weighted average radiant
temperature of the surfaces surrounding the person--is one factor determining
thermal comfort. The combination of a very hot radiant source having only a
small area (such as a quartz radiant heater) and large, cool walls can yield an
acceptable average radiant temperature. The relationship between the mean
radiant temperature and the air temperature is shown in Figure 4. There is a
direct tradeoff between MRT and air temperature. A constant comfort level can
be approximately maintained by raising the MRT 1deg.F and setting back the
thermostat 1deg.F. Many people sense that the room is more comfortable after
increasing the radiant temperature, but they are unable to attribute it to a
particular difference. A room with high radiant temperatures simply "feels"
more comfortable. Others comment that the temperature seems more constant.
To increase the mean radiant temperature in a room, eliminate cold surfaces.
The window is the first culprit (if no sun is shining though it). Windows make
a disproportionately large contribution to a low mean radiant temperature
because they are so cold. Somebody sitting near a window on a 0deg.F winter day
will need a 9deg.F higher air temperature to maintain thermal comfort. (lf
unable to turn up the heat, most people move, put on warmer clothes or
complain.) The temperature of a single-glazed window's inside surface--that's
the one that counts--will be less than halfway between the outside and inside
temperature.
There are many ways to increase a window's radiant temperature. The cheapest
retrofit is a heavy curtain or a piece of rigid foam insulation (which is more
effective). A heavy curtain shields the cold window and presents a new interior
surface that is much closer to room temperature. Installing a double-glazed or
storm window will raise the surface temperature so that it is about 5/8 of the
outside-inside temperature difference. Triple-glazed windows present an even
warmer inside surface. Of course, one should make the north-facing windows the
first target of any retrofit.
An invisible benefit of insulating the ceiling and walls is an increase in
radiant temperature. The increase may be relatively small compared to window
improvements, but the large area affected results in a significant increase in
mean radiant temperature--sometimes worth a few degrees of air temperature.
Again, occupants often indicate that the house feels warmer, or more evenly
heated, after insulating.
Installing radiant heating ceiling panels is another way of increasing a room's
MRT. These panels contain wires heated by electrical resistance. The
manufacturers argue that lower inside air temperatures are possible with
radiant heating, so radiant panels should should be considered a conservation
measure. (They typically contend that the higher MRT permits a 5deg.F lower air
temperature.) The argument has some merit but the heat may still be more
expensive because it is electric resistance and some heat may be lost upwards,
into the ceiling. Another problem is that the untrained consumer may still put
the thermostat at 70deg.F, so no energy is saved. If, however, radiant panels
are installed in conjunction with a "comfortstat," that is, a device that
measures thermal comfort based on both air and radiant temperature, energy
savings would be more certain.
It is difficult to calculate the savings, but any single action (wall
insulation, ceiling insulation, or window upgrade) should permit a 2deg.F
setback while maintaining constant thermal comfort.
Recommendations
Thermal comfort means much more than just a high thermostat setting.
Comfort depends on the occupants' clothing and activity levels, and on a home's
construction features, including air flow and mean radiant temperature. These
factors can be modified through retrofits and careful recommendations to permit
a lower thermostat setting and energy savings, while keeping occupants just as
comfortable. Major retrofits, such as insulation, window treatments, and
house-tightening, should be accompanied by thermostat setbacks of 1-5deg.F.
Also, the location of activities inside the home should be examined from the
perspective of drafts and low radiant temperatures. Even a modest repositioning
of furniture or small retrofits can can vastly enhance thermal
comfort. n
Table 1. Clo-Values for Different Items of Clothing and Ensembles
Clothing Clo-value
___________________________________________________________
Naked 0.0
Briefs 0.06
T-shirt 0.09
Bra and panties 0.05
Long underwear
upper 0.35
lower 0.35
Shirt
light, short sleeve 0.14
heavy, long sleeve 0.29
Add 5% for tie or turtleneck
Skirt 0.22-0.70
Trousers 0.26-0.32
Sweater 0.20-0.37
Socks 0.04-0.10
0.02-0.08
Light summer outfit 0.3
Working clothes 0.8
Typical indoor winter clothing combination 1.0
Heavy business suit 1.5
__________________________________________________________________________
Note: The clo-value is a measure of insulation provided by articles of
clothing. A clo-value of 1 roughly equals R-0.88. Clo-values are additive, so
one can calculate the clo-value for a person wearing a T-shirt and light socks
(0.09 + 0.04) = 0.13. (Adapted from ASHRAE Fundamentals and "Technical
Review of Thermal Comfort," Bruel and Kjaer, No. 2, 1982.)

Figure 1. The potential for offsetting reductions in air temperature with
increases in other parameters. Major parameters include insulation value
of clothing, activity level, air movement, and mean radiant temperature of
surfaces (although in this diagram they have been graphed on an arbitrary
scale). Thermal comfort measures can also make a home more comfortable without
increasing heating energy use. Such measures correspond to shifting to a higher
line of thermal comfort.

Figure 2. The relationship between clo-value and thermal comfort. A person
can maintain a constant level of thermal comfort at colder air temperatures by
putting on more clothes. (An obvious concept, but for once it is quantified.) A
nude person has clo-0.0 and a standard business suit is about clo-1.0.
Table 2. Met-values for selected activities
Activity Mets
________________________________________________________________
Sleeping 0.7
Seated, quiet 1.0
Reading Home Energy articles 1.2
Standing 1.2
Walking, level
3 feet/sec 2.0
6 feet/sec 3.8
House cleaning 2.0-3.4
Cooking 1.6-2.0
Typing 1.2-1.4
Driving 1.5
Writing Home Energy articles 1-5
Dancing 2.4-4.4
Calisthenics 3.0-4.0
Carpentry, sawing 2.0
Basketball 5.0-7.6
Wrestling 7.0-8.7
________________________________________________________________
Note: A met corresponds to 58 W per square meter of body surface area (18.4 Btu
per hour per square foot). For the average man, one met corresponds to roughly
100 W. These numbers are only approximate but indicate the range of typical
metabolic rates. (Adapted from ASHRAE Fundamentals.)

Figure 3. The effect of air movement on comfort. A person needs higher air
temperatures to maintain comfort when air moves past them. Air movement can
change the comfort temperature as much as 5deg.F under typical domestic
conditions. The elbows in the comfort curves reflect the destruction of the
body's surface air film. As air speeds increase above 0.3 feet per second, the
surface air film collapses and ceases to provide insulation. Heat loss
increases markedly, which causes increased discomfort.

Figure 4. The relationship between the mean radiant temperature and air
temperature. There is a direct tradeoff between MRT and air temperature. An
approximately constant comfort level can be maintained by raising the MRT
1deg.F and setting back the thermostat 1deg.F.
Related Articles
"Profiles of Multifamily Weatherization Projects: A Tale of Five Cities" (Kinney, Wilson, and MacDonald) "Selecting Windows for Energy Efficiency" (Warner) "Shade Trees as a Demand-Side Resource" (McPherson and Simpson) "Sizing Up Skylights" (Warner) "Weatherization Assistance: The Fuel Oil Study" (Ternes and Levins)
| Back to Contents Page |
Home Energy Index |
About Home Energy |
| Home Energy Home Page | Back Issues of Home Energy |
Home Energy can be reached at: contact@homeenergy.org
Home Energy magazine -- Please read our Copyright Notice
|