FREE CONTENT

Editorial: ERVs Get The Yellow Flag

September 01, 2010
September/October 2010
This article originally appeared in the September/October 2010 issue of Home Energy Magazine.
SHARE
Click here to read more articles about Editorials

As we make homes tighter, we need to provide ventilation, which costs energy. One way to reduce the energy impact of that ventilation is to use an air-to-air heat recovery system. A heat recovery ventilator (HRV) recovers sensible heat by exchanging heat between incoming and outgoing airstreams. An energy recovery ventilator (ERV) is similar to an HRV but also allows moisture to be exchanged.



(KyotoCooling)

ERVs make a lot of sense both in hot-humid climates and in cold climates. In the former they reduce the dehumidification load by keeping excess moisture out; in the latter they reduce the humidification load by keeping moisture in. Nevertheless, there are reasons why one may wish to be cautious in using ERVs.

ERVs do not make a lot of sense when you want to exhaust excess indoor moisture and replace it with drier outdoor air. Many codes (and ASHRAE Standard 62.2) require kitchen and/or bath exhaust to allow the removal of excess moisture. Running these exhausts through an ERV would recover this moisture and dump it back in house. Rarely is this what one wants to do. Yet there is a growing segment of building professionals who are using ERVs in exactly this way. It is not clear whether this use of an ERV meets the requirement of exhaust, but it does seem clear that it could cause moisture problems.

An even more disconcerting issue is the fact that some ERVs can “recover” formaldehyde in the same way that they recover water. Recent research has confirmed what many of us suspected—that there are hazardous concentrations of formaldehyde in many homes. While the ultimate solution may be source control, dilution ventilation is a key method of reducing indoor concentration. Having ERVs that recover formaldehyde represents a serious risk.

Because water and formaldehyde are reasonably similar chemically, it is not surprising that the mechanisms that would recover water could recover formaldehyde. Research has shown that specific materials (for example, certain desiccants and plastics) can do a good job of this. That is not to say, however, that all ERVs do, in fact, recover formaldehyde. Clever designs of materials, layers, coatings, membranes, and so forth could in theory make ERVs highly selective. There is, unfortunately, almost no data available on the performance of ERVs currently on the market with respect to formaldehyde (or other contaminants). Such test data is needed on the various ERVs in the marketplace. Unless one knows that formaldehyde is not a contaminant of concern, one should probably be cautious in using ERVs.

The yellow flag is out on energy recovery ventilators.

Max Sherman is a senior scientist in the Environmental Energy Technologies Division at Lawrence Berkeley National Laboratory and a frequent contributor to Home Energy.

  • 1
  • FIRST PAGE
  • PREVIOUS PAGE
  • NEXT
  • LAST
Click here to view this article on a single page.
© Home Energy Magazine 2014, all rights reserved. For permission to reprint, please send an e-mail to contact@homeenergy.org.
Home Energy Pros
Discuss this article with other home performance professionals at Home Energy Pros!.

Comments
Add a new article comment!

Enter your comments in the box below:

(Please note that all comments are subject to review prior to posting.)

 

While we will do our best to monitor all comments and blog posts for accuracy and relevancy, Home Energy is not responsible for content posted by our readers or third parties. Home Energy reserves the right to edit or remove comments or blog posts that do not meet our community guidelines.

Related Articles
Email Newsletter

Home Energy E-Newsletter

Sign up for our free monthly
E-Newsletter!

Harness the power of
HOME PERFORMANCE!

Get the Home Energy
e-newsletter

FREE!

SUBSCRIBE

NOW!